Oversetter...
xxxx 0010
Unknown Command
Beckhoff · TwinSAFE Logic FB
Hva betyr xxxx 0010 ?
An unknown command was received over the FSoE connection. This signifies a command that the recipient device does not recognize or support. It suggests a configuration error or an attempt to use unsupported functionality, potentially disrupting safety communication and causing a shutdown.
Vanlige årsaker
- Received a command that is not defined or supported.
- Attempt to execute a non-existent function.
- Command protocol mismatch.
- Outdated firmware unable to interpret command.
- Reserved command code used incorrectly.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Confirm that the FSoE master and slave configurations are identical and use compatible command sets.
- 2
Update firmware on devices if new command sets are required for functionality.
- 3
Analyze the FSoE master logic to ensure it is sending only documented and supported commands.
- 4
Check for external interference on the network cabling that might corrupt command packets.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Beckhoff TwinSAFE Logic FB