E2819

Mains failure

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E2819 ?

Complete loss of incoming AC mains power supply to the drive. This results in an immediate loss of power to the control and power sections.

Vanlige årsaker

  • Complete loss of incoming AC mains power.
  • Main circuit breaker tripped or fuse blown for the entire supply.
  • Emergency stop activated, cutting off mains power.
  • Faulty power cable or connection.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the presence of incoming AC mains voltage at the drive's input terminals.

  2. 2

    Check the main circuit breaker and any upstream protective devices for tripped conditions or blown fuses.

  3. 3

    Inspect the mains power cabling from the supply point to the drive for any breaks or loose connections.

  4. 4

    Confirm that no emergency stop or safety circuit has activated, cutting off the main power supply.

Se alle koder i denne manualen (66)