E8029
Positive position limit exceeded
Bosch Rexroth · IndraDrive C Drive Controllers
Hva betyr E8029 ?
The actual or commanded position has exceeded the configured positive software travel limit. This can lead to the machine reaching its mechanical hard stop or unexpected motion.
Vanlige årsaker
- Programmed motion or jog command attempts to move beyond the positive software travel limit.
- Incorrectly set positive software limit parameter.
- Loss of position feedback or incorrect encoder scaling, leading to misinterpretation of actual position.
- Mechanical overtravel due to inertia or incorrect braking.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the positive software travel limit parameter in the drive controller and ensure it is set correctly and safely for the application.
- 2
Check the commanded position values in the motion program to ensure they do not exceed the positive travel limit.
- 3
Inspect the position feedback system for encoder accuracy and scaling parameters.
- 4
Manually jog the axis to a safe position within the valid travel range.