Oversetter...
E8030
Negative position limit exceeded
Bosch Rexroth · IndraDrive C Drive Controllers
Hva betyr E8030 ?
The actual or commanded position has exceeded the configured negative software travel limit. This can lead to the machine reaching its mechanical hard stop or unexpected motion.
Vanlige årsaker
- Programmed motion or jog command attempts to move beyond the negative software travel limit.
- Incorrectly set negative software limit parameter.
- Loss of position feedback or incorrect encoder scaling, leading to misinterpretation of actual position.
- Mechanical overtravel due to inertia or incorrect braking.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the negative software travel limit parameter in the drive controller and ensure it is set correctly and safely for the application.
- 2
Check the commanded position values in the motion program to ensure they do not exceed the negative travel limit.
- 3
Inspect the position feedback system for encoder accuracy and scaling parameters.
- 4
Manually jog the axis to a safe position within the valid travel range.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Bosch Rexroth IndraDrive C Drive Controllers