Oversetter...
E8043

Positive travel range limit switch activated

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E8043 ?

The positive hardware travel limit switch has been activated, indicating that the axis has reached its maximum physical travel in the positive direction. This typically results in a controlled stop.

Vanlige årsaker

  • Programmed motion or jog command caused the axis to activate the positive limit switch.
  • Incorrectly set software limits, allowing motion to reach the hardware limit.
  • Mechanical overtravel due to inertia or incorrect braking after the software limit.
  • Faulty positive limit switch or its wiring.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Manually jog the axis in the negative direction to clear the limit switch and return to a safe operating range.

  2. 2

    Verify the positive software travel limit parameter in the drive controller and adjust it to be inside the hardware limit.

  3. 3

    Inspect the positive limit switch for physical damage, proper mounting, and verify its wiring for continuity.

  4. 4

    Check the motion program for any commands that might cause the axis to intentionally or unintentionally hit the limit switch.

Se alle koder i denne manualen (66)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive C Drive Controllers