E8044

Negative travel range limit switch activated

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E8044 ?

The negative hardware travel limit switch has been activated, indicating that the axis has reached its maximum physical travel in the negative direction. This typically results in a controlled stop.

Vanlige årsaker

  • Programmed motion or jog command caused the axis to activate the negative limit switch.
  • Incorrectly set software limits, allowing motion to reach the hardware limit.
  • Mechanical overtravel due to inertia or incorrect braking after the software limit.
  • Faulty negative limit switch or its wiring.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Manually jog the axis in the positive direction to clear the limit switch and return to a safe operating range.

  2. 2

    Verify the negative software travel limit parameter in the drive controller and adjust it to be inside the hardware limit.

  3. 3

    Inspect the negative limit switch for physical damage, proper mounting, and verify its wiring for continuity.

  4. 4

    Check the motion program for any commands that might cause the axis to intentionally or unintentionally hit the limit switch.

Se alle koder i denne manualen (66)