E8260

Torque/force command value limit active

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr E8260 ?

The commanded torque or force value has reached the maximum configured limit, indicating that the drive is restricting the output to prevent exceeding its operational boundaries or protecting the mechanical system.

Vanlige årsaker

  • Programmed torque/force command exceeds the configured limit parameter in the drive.
  • Application requires more torque/force than allowed by the current parameter settings.
  • Torque/force limit parameter set too low for the application requirements.
  • External command from PLC/HMI is intentionally limiting the torque/force.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the torque/force command value in the motion program and ensure it is within the configured limit.

  2. 2

    Check the drive parameter for the torque/force limit and adjust it if necessary, ensuring it is appropriate for the application and mechanical system.

  3. 3

    Assess the mechanical load and operation to determine if the commanded torque/force is actually required.

  4. 4

    Ensure no external control system (e.g., PLC) is imposing an overly restrictive torque/force limit.

Se alle koder i denne manualen (66)