Oversetter...
F2008

The motor type has changed.

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr F2008 ?

The drive has detected a change in the connected motor type compared to the previously stored configuration. This requires a parameter adjustment to ensure correct motor control.

Vanlige årsaker

  • The physical motor connected to the drive has been replaced with a different type or model.
  • Motor parameters in the drive's configuration have been changed to a different motor type without confirmation.
  • A drive configuration (e.g., from MMC) for a different motor has been loaded.
  • Internal drive error misidentifying the motor.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify that the currently connected motor matches the motor type configured in the drive's parameters. Compare motor nameplate data.

  2. 2

    If the motor was replaced, update the drive parameters to match the new motor's specifications. This may require recalibration.

  3. 3

    If a different configuration was loaded, ensure it corresponds to the actual motor connected.

  4. 4

    Acknowledge the motor type change in the drive's software, if prompted, and save the new configuration.

Se alle koder i denne manualen (66)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive C Drive Controllers