Load parameter default values
Bosch Rexroth · IndraDrive C Drive Controllers
Hva betyr F2009 ?
The drive is indicating that it is loading default parameter values. This can happen during initial setup, after a parameter reset, or if configuration data is lost.
Vanlige årsaker
- Drive detected corrupted or missing parameter values and loaded factory defaults.
- A command to load default parameters was executed.
- MMC card with custom parameters is not present or readable, forcing the drive to internal defaults.
- First power-up of a new or reset drive.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Determine if loading default parameters was an intentional action. If not, investigate why parameters might have been lost or corrupted.
- 2
Reload the correct application-specific parameter set into the drive from a backup source (e.g., MMC, programming software).
- 3
Ensure the MMC card containing the correct parameters is securely inserted and readable.
- 4
After loading parameters, cycle power to the drive to ensure they are fully initialized.
Verifisert teknisk data. Sist oppdatert: March 2026