F2018

Device overtemperature shutdown

Bosch Rexroth · IndraDrive C Drive Controllers

Hva betyr F2018 ?

The drive controller or associated power electronics have reached a critical internal temperature, triggering a safety shutdown to prevent damage. This is a severe thermal event.

Vanlige årsaker

  • Inadequate cooling for the drive due to blocked vents, fan failure, or high ambient temperature.
  • Sustained operation at or above the drive's rated output current.
  • Internal thermal sensor malfunction or incorrect reading.
  • Failure of internal cooling components.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Allow the drive controller to cool down completely before attempting to reset the fault.

  2. 2

    Check the drive's cooling fan for proper operation. Verify airflow direction and ensure no obstructions in the heatsink or ventilation openings.

  3. 3

    Measure the ambient temperature around the drive and ensure it is within the specified operating range.

  4. 4

    Reduce the load on the drive if possible, or verify that the drive is correctly sized for the application's continuous and peak current requirements.

Se alle koder i denne manualen (66)