Oversetter...
F2105

Impossible to address Hiperface memory

Bosch Rexroth · IndraDrive MPx02

Hva betyr F2105 ?

The drive's control system failed to establish communication or access data within the Hiperface memory. This often indicates a corrupted memory module, a physical connection issue, or an internal hardware defect related to the memory interface. Such a fault can prevent the drive from booting, loading essential configuration data, or operating correctly.

Vanlige årsaker

  • Corrupted Hiperface memory data
  • Faulty Hiperface memory module hardware
  • Loose or damaged connection to Hiperface memory
  • Incorrect memory module installed
  • Software or firmware error affecting memory access

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the Hiperface encoder cable for physical damage, proper seating, and secure connections at both the motor and the drive.

  2. 2

    Verify Hiperface encoder connector pins on both the motor and the drive are clean, free from corrosion, and not bent or damaged.

  3. 3

    Check drive parameters related to the Hiperface interface (e.g., motor type, encoder type, encoder ID) for correct configuration against the motor's technical data.

  4. 4

    Measure the supply voltage output from the drive's Hiperface interface to the encoder to confirm it is within specified limits according to the drive manual.

Se alle koder i denne manualen (99)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive MPx02