F2840

Error supply shutdown

Bosch Rexroth · IndraDrive MPx02

Hva betyr F2840 ?

An error occurred during the process of shutting down the power supply. This could indicate a problem with the controlled discharge of DC bus capacitors, a failure in the power-down sequence, or an inability to fully remove power. An uncontrolled shutdown can risk personnel safety or damage sensitive components.

Vanlige årsaker

  • Fault in the power supply discharge circuit
  • Failure of shutdown relays or contactors
  • Incorrect shutdown sequence execution by firmware
  • External fault preventing complete power removal
  • Persistent voltage on critical components after shutdown command

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the stability and integrity of the incoming AC supply voltage at the drive's input terminals throughout the power-down sequence.

  2. 2

    Inspect all control wiring and connections (e.g., X10, X31/X32 connectors for STO/HSO) for loose terminals, damage, or contamination that could interrupt the shutdown signal path.

  3. 3

    Check the drive parameters related to DC bus monitoring, discharge control, and power-down thresholds against the machine's commissioning documentation.

  4. 4

    Safely measure and monitor the DC bus voltage discharge rate immediately after a shutdown command to identify any uncontrolled or abnormally slow/fast decay.

  5. 5

    Inspect the external braking resistor (if connected) and its wiring for proper termination, resistance value, and absence of short or open circuits that could interfere with DC bus energy dissipation.