Hardware variant not supported
Bosch Rexroth · IndraDrive MPx02
Hva betyr F2892 ?
The detected hardware variant of the drive or an installed module is not supported by the current firmware. This typically occurs when a new or different hardware version is used with an older or incompatible firmware release. The drive will not be able to operate safely or correctly without compatible firmware.
Vanlige årsaker
- Firmware version is too old for the installed hardware
- Hardware is not officially supported by the drive system
- Incorrect hardware module installed (e.g., wrong revision)
- Mismatch between control and power section hardware versions
- Corrupted firmware preventing proper hardware recognition
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the exact part numbers and revision levels of the IndraDrive MPx02 and all installed option modules by physically inspecting their labels.
- 2
Check the currently installed firmware version of the IndraDrive MPx02 via the drive's display or using Bosch Rexroth IndraWorks diagnostic software.
- 3
Consult Bosch Rexroth documentation (e.g., firmware release notes, compatibility lists) to determine the compatible firmware version for the detected hardware variant(s).
- 4
Review the system's maintenance logs or installation records to identify any recent hardware replacements or upgrades of the drive or its modules.