Oversetter...
F3111

Refer. missing when selecting safety related end pos.

Bosch Rexroth · IndraDrive MPx02

Hva betyr F3111 ?

This non-fatal safety technology error indicates that a safety-related reference or datum is missing when attempting to select a safety-related end position. This prevents the drive from reliably establishing its safe operating limits, impacting safety functions like Safe Limited Position (SLP).

Vanlige årsaker

  • Safety reference point for the axis has not been set or is corrupted.
  • Encoder fault preventing accurate position feedback for safety functions.
  • Incorrect configuration of safety parameters related to reference positions (e.g., S-0-0193, S-0-0194).
  • Problem with the safety encoder or its connection to the IndraDrive MPx02.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify that the safety reference point for the axis has been correctly established and stored according to the machine's commissioning procedure.

  2. 2

    Check the primary and secondary encoder feedback signals for integrity and proper operation.

  3. 3

    Review safety parameters in the IndraDrive MPx02, specifically those defining reference positions and safety limits, to ensure correct configuration.

  4. 4

    Inspect the wiring and connections of the safety encoder for damage, loose terminals, or improper shielding.

  5. 5

    If an external safety PLC is used, verify its programming and communication with the IndraDrive MPx02 regarding reference position management.

Se alle koder i denne manualen (99)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive MPx02