F7010

Safety related limited increment exceeded

Bosch Rexroth · IndraDrive MPx02

Hva betyr F7010 ?

This safety technology error indicates that the actual position increment of the motor, as monitored by the safety function, has exceeded a defined safety-related limited increment threshold on the IndraDrive MPx02. This typically means the motor moved further than permitted in a safe monitored mode, triggering a safety stop.

Vanlige årsaker

  • Incorrectly parameterized safety-related limited increment (e.g., S-0-0196) for the application.
  • Loss of control due to incorrect speed loop tuning or mechanical issues.
  • Encoder fault or noise leading to erroneous position feedback.
  • Commanded motion exceeding the safety-monitored increment.
  • Unexpected external force causing the axis to move beyond the allowed increment.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review and adjust the safety-related limited increment parameter (e.g., S-0-0196 'Limited increment position range') in the IndraDrive MPx02, ensuring it is appropriate for the application.

  2. 2

    Check the tuning of the speed and position control loops for stability and accuracy.

  3. 3

    Verify the motor encoder for correct and clean position feedback. Inspect wiring for noise or loose connections.

  4. 4

    Analyze the machine's motion profile and ensure that commanded position changes do not exceed the set safety increment.

  5. 5

    Inspect the mechanical system for any binding, excessive backlash, or external forces that could cause unintended movement.