Oversetter...
F7014

Acceleration threshold exceeded

Bosch Rexroth · IndraDrive MPx02

Hva betyr F7014 ?

This safety technology error indicates that the actual acceleration of the motor has exceeded a safety-related acceleration threshold configured in the IndraDrive MPx02. This is a critical safety violation, implying an uncontrolled or excessively rapid change in speed, leading to an immediate safety stop.

Vanlige årsaker

  • Incorrectly parameterized safety-related acceleration threshold (e.g., S-0-0092 'Maximum acceleration') for the application.
  • Aggressive tuning of the speed or current control loops, causing overshoot during acceleration/deceleration.
  • Mechanical shock or sudden load change causing high acceleration.
  • Encoder fault or noise leading to erroneous acceleration calculation.
  • Commanded acceleration exceeding the safe limit for the selected operating conditions.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review and adjust the safety-related acceleration threshold parameters (e.g., S-0-0092) in the IndraDrive MPx02, ensuring they are appropriate for the application's safety requirements.

  2. 2

    Check the tuning of the current and velocity control loops, specifically feed-forward and gain settings, to prevent overshoot.

  3. 3

    Inspect the mechanical system for any sudden load changes, binding, or play that could induce high acceleration spikes.

  4. 4

    Verify the motor encoder for accurate feedback, as noisy position data can lead to erroneous acceleration calculations.

  5. 5

    Analyze the commanded motion profile to ensure that programmed acceleration ramps do not exceed the safety threshold.

Se alle koder i denne manualen (99)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Bosch Rexroth IndraDrive MPx02