Oversetter...
E3104
Plausibility error of safety parameters
Bosch Rexroth · IndraDrive Troubleshooting
Hva betyr E3104 ?
This warning occurs in normal operation when safety technology is activated. It indicates a comparison showed that channel 1 and channel 2 are not operating with the same safety parameters. If a safety function is selected, this condition would trigger the F3140 Plausibility error of safety parameters error.
Vanlige årsaker
- Channel 1 and channel 2 are not working with the same safety parameters.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Execute command P-0-3204 (Synchronize and store safety technology IDN command) to make channel 2 accept the parameters of channel 1.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Bosch Rexroth IndraDrive Troubleshooting