Oversetter...
750
Spindle Amplifier Not Activated (16i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Hva betyr 750 ?
The serial spindle amplifier for Series 16i was not activated normally at power-on time. This suggests an issue with the amplifier's internal readiness or its startup sequence.
Vanlige årsaker
- The spindle amplifier failed to acknowledge the activation command from the controller.
- Power supply issues to the spindle amplifier during the activation sequence.
- A fault condition within the spindle amplifier prevented normal activation.
- Incorrect serial communication setup for the spindle amplifier.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the DC bus voltage at the spindle amplifier's power input terminals (L1, L2, L3).
- 2
Verify the serial communication signal status line from the controller to the spindle amplifier.
- 3
Inspect the spindle amplifier's internal status LEDs for any fault indications.
- 4
Confirm the spindle amplifier's unique address is correctly configured.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters