Oversetter...
A

Cooling Fan Stop (Control Module) (ECM)

Fanuc · Alpha i Series AC Servo Motor and Spindle

Hva betyr A ?

The cooling fan for the heat sink of the Control Module has stopped. This can lead to overheating of the Control Module and reduced operating life of its components. Note that even if ECM works continuously, the cooling fan should be exchanged early.

Vanlige årsaker

  • Current exceeds limits during regenerative braking.
  • Excessive back EMF from the motor during deceleration.
  • Braking resistor capacity is insufficient.
  • Incorrect regeneration control parameters.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the cooling fan of the Control Module for obstructions or mechanical failure.

  2. 2

    Measure the voltage supply to the cooling fan to ensure it is receiving power.

  3. 3

    Replace the cooling fan if it is not operating or is making abnormal noise.

Se alle koder i denne manualen (29)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Alpha i Series AC Servo Motor and Spindle