J
Over-heat of Resistor Module (ECM)
Fanuc · Alpha i Series AC Servo Motor and Spindle
Hva betyr J ?
The Resistor Module has detected an abnormal temperature, indicating overheating. This is typically detected by a built-in thermostat.
Vanlige årsaker
- The temperature of the braking resistor module has exceeded its safe operating limit.
- Braking resistor is continuously subjected to high power dissipation.
- Inadequate cooling or ventilation of the braking resistor assembly.
- Faulty temperature sensor within the braking resistor module.
- Overload condition causing excessive regenerative energy.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check for blockages to airflow around the Resistor Module.
- 2
Verify the operation of any cooling fans associated with the Resistor Module.
- 3
Ensure the discharge duty cycle is within specifications; excessive regeneration can cause overheating.