0435
Velocity Loop Integral Gain Overflow
Fanuc · Alpha i Series Servo Amplifier
Hva betyr 0435 ?
This invalid parameter setting alarm indicates that the internal calculation value of the velocity loop integral gain has overflowed. This typically occurs when the parameter setting for the integral gain is excessively high, leading to calculation errors.
Vanlige årsaker
- Integral term in the velocity control loop has exceeded its maximum allowable value.
- Sustained difference between commanded and actual velocity.
- Improper velocity loop integral gain setting (P04-11).
- Load torque variations beyond control limits.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Decrease the value of the velocity loop integral gain parameter.