Oversetter...
0885

Machine Velocity Feedback Coefficient Overflow

Fanuc · Alpha i Series Servo Amplifier

Hva betyr 0885 ?

This invalid parameter setting alarm indicates that the internal calculation value of the machine velocity feedback coefficient has overflowed. This usually happens if the coefficient is set too high, exceeding internal processing limits.

Vanlige årsaker

  • The calculated machine velocity feedback coefficient is too high.
  • A sensor reading related to machine speed has overflowed during coefficient calculation.
  • Parameter P601.2 (Velocity Feedback Coefficient) is set too high.
  • An internal process overflowed during the calculation of the velocity feedback gain.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Decrease the machine velocity feedback coefficient.

  2. 2

    Alternatively, utilize the vibration-damping control function, which offers an equivalent effect.

Se alle koder i denne manualen (101)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Alpha i Series Servo Amplifier