SP9070

ILLEGAL AXIS DATA

Fanuc · Alpha i Series Servo Amplifier

Hva betyr SP9070 ?

The spindle detected a mismatch between the spindle amplifier connection state and its hardware setting. This alarm can be issued if the spindle amplifier configuration has been changed without corresponding software updates or if there is a wiring issue.

Vanlige årsaker

  • Invalid or inconsistent axis data within the system's memory.
  • Mismatch in motor encoder counts or resolutions.
  • Configuration parameter for axis type or limits is incorrect.
  • Data corruption related to axis calibration.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the physical connection state of the spindle amplifier.

  2. 2

    Verify the spindle amplifier hardware settings for correctness.

  3. 3

    If the spindle amplifier configuration was recently changed, correct the settings on the spindle amplifier side to match the actual configuration.