SV0488

SELF TEST OVER TIME

Fanuc · Alpha i Series Servo Amplifier

Hva betyr SV0488 ?

The MCC off Test was not completed within the time specified by parameter No. 1946. This indicates a potential issue with the MCC (Motor Contactor) contact operation, its wiring, or an inappropriately set test time.

Vanlige årsaker

  • Internal self-test routine of the control system took longer than the defined time limit.
  • CPU overload or slow response impacting internal diagnostics.
  • Memory access issues during self-test.
  • Complex operation slowing down system initialization.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the MCC (Motor Contactor) contact for proper operation, mechanical integrity, and wear.

  2. 2

    Verify the value of parameter No. 1946, which defines the maximum allowable time for the MCC off Test, and adjust if necessary.