Oversetter...
SRVO-089

Line Tracking Motor Overheat

Fanuc · R-30iB Mate + Mate Plus Robot

Hva betyr SRVO-089 ?

The motor connected to the line tracking encoder has overheated. This alarm persists even after the Pulsecoder has cooled sufficiently and power is reapplied, indicating a persistent overheating condition or sensor issue.

Vanlige årsaker

  • Overheating of the motor driving the line tracking encoder.
  • Excessive load on the line tracking axis exceeding motor thermal limits.
  • Malfunction of the motor's internal thermal protection sensor.
  • Inadequate cooling to the line tracking motor housing.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure motor winding resistance. Compare values to P1-54 specifications.

  2. 2

    Check motor encoder signal integrity at terminal E1-E4.

  3. 3

    Verify cooling fan operation for the line tracking motor assembly.

  4. 4

    Inspect motor mounting for proper heat dissipation.

  5. 5

    Monitor motor temperature via parameter P1-78 during operation.

Se alle koder i denne manualen (53)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc R-30iB Mate + Mate Plus Robot