SRVO-092

Line Tracking Pulsecoder Communication Start/Stop Bit Error

Fanuc · R-30iB Mate + Mate Plus Robot

Hva betyr SRVO-092 ?

Communication between the Pulsecoder and the line tracking board is abnormal, specifically indicating a Start/Stop Bit Error (STBERR). This signifies a problem with the framing of serial data packets.

Vanlige årsaker

  • Incorrect start or stop bit signaling from the line tracking pulsecoder.
  • Line tracking pulsecoder unit not adhering to communication protocol timing.
  • Signal integrity issues affecting start/stop bit detection.
  • Faulty line tracking pulsecoder generating invalid serial framing.
  • Servo controller expecting a different communication frame structure.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the connection cable at each end (the line tracking board and the Pulsecoder).

  2. 2

    Check whether the shielding of the connection cable is securely connected to the grounding plate.

  3. 3

    Replace the Pulsecoder.

  4. 4

    Replace the line tracking cable.

  5. 5

    Replace the line tracking board.