SRVO-235

Short Term Single Chain Failure

Fanuc · R-30iB Mate + Mate Plus Robot

Hva betyr SRVO-235 ?

A short-term single chain failure condition is detected. This can be caused by a momentary or 'half' release of the DEADMAN switch or a 'half' operation of the emergency stop switch, indicating a transient safety circuit anomaly.

Vanlige årsaker

  • Temporary failure in a servo drive's communication chain or power supply.
  • Brief interruption in the feedback signal from a single motor in a multi-axis configuration.
  • Momentary voltage fluctuation affecting servo amplifier performance.
  • Loose connection in the power or signal wiring for a servo axis.
  • Transient overload condition on a specific servo axis.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Cause the same error to occur again, and then perform the alarm resetting procedure.

  2. 2

    Replace the emergency stop board.

  3. 3

    Replace the 6-Axis servo amplifier.

Se alle koder i denne manualen (53)
Verifisert teknisk data. Sist oppdatert: March 2026