Oversetter...
368

SERIAL DATA ERROR(INT)

Fanuc · Series 0i-D/0i Mate-D Maintenance

Hva betyr 368 ?

This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders signifies a communication interruption with the built-in Pulsecoder. Common causes are cable disconnection, Pulsecoder failure, or external noise.

Vanlige årsaker

  • Physical disconnection or damage to the Pulsecoder communication cable.
  • Internal failure of the Pulsecoder preventing serial data transmission.
  • Electrical noise interfering with the serial data communication.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the Pulsecoder cable for physical damage, such as cuts, abrasions, or crushed sections.

  2. 2

    Verify all connections of the Pulsecoder cable are secure at both the Pulsecoder and the servo amplifier.

  3. 3

    Check for and mitigate sources of electrical noise (e.g., from power lines, solenoids) that could interrupt serial communication.

  4. 4

    Perform a continuity test on each conductor of the Pulsecoder cable to rule out internal wire breaks.

  5. 5

    If cable integrity and noise issues are ruled out, replace the Pulsecoder unit.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Series 0i-D/0i Mate-D Maintenance