DS0005

EXCESS MAXIMUM ACCELERATION

Fanuc · Series 0i-D/0i Mate-D Maintenance

Hva betyr DS0005 ?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected a command specifying an acceleration value that exceeds the machine's maximum allowable acceleration for the axis.

Vanlige årsaker

  • NC program commands excessively high acceleration rates for the axis.
  • Machine parameters for acceleration time constants or jerk limits are set too aggressively.
  • Mechanical binding, excessive friction, or backlash preventing the axis from achieving commanded acceleration.
  • Limitations of the servo amplifier or motor preventing the commanded acceleration.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review the NC program for any movements that imply excessively high acceleration, particularly during rapid changes in direction or speed.

  2. 2

    Verify the machine's acceleration parameters for the affected axis (e.g., parameters related to acceleration time constants or jerk limits).

  3. 3

    Inspect the mechanical system for any binding, excessive friction, or backlash that could prevent the axis from achieving commanded acceleration.

  4. 4

    Check for any related servo alarms on the drive system that might indicate an inability to meet acceleration commands.

  5. 5

    Adjust the acceleration parameters to more conservative values and test the machine's movement to prevent over-acceleration.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026