ILLEGAL EXECUTION SEQUENCE
Fanuc · Series 0i-D/0i Mate-D Maintenance
Hva betyr DS0006 ?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected an illegal execution sequence. This implies a logic error in the program or an unexpected state transition.
Vanlige årsaker
- Logic error in the NC program or PMC ladder logic leading to an invalid command sequence.
- Incorrect macro program execution or unexpected M-code/T-code call.
- Corrupted NC program data or PMC program causing irregular flow.
- Unexpected machine state transition during program execution.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Review the NC program and PMC ladder logic for any sequences that could lead to an invalid or unexpected command execution.
- 2
Check for any conditional logic (e.g., IF statements, GOTO commands) that might lead to an unintended program flow.
- 3
Verify the machine's current operational mode and state transitions (e.g., manual to auto, program restart) for any irregularities.
- 4
Examine any recently modified programs or macros for logical errors or unsupported commands.
- 5
Perform a step-by-step execution of the program in single-block mode to pinpoint the exact point of the illegal sequence.