Request for Reference Position Return
Fanuc · Series 20 CNC
Hva betyr 300 ?
This alarm typically indicates that an operation requiring the machine to be at its reference (home) position was initiated before the reference return cycle was completed. It serves as a reminder or pre-alarm that homing is required.
Vanlige årsaker
- Attempting to run an automatic program or move an axis in absolute coordinates before homing.
- Power cycling the machine without re-establishing reference positions.
- Machine parameters requiring explicit homing after certain events.
- Loss of absolute position data due to battery failure or encoder issues (leading to a need for homing).
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Perform the reference position return (homing) procedure for all axes as per the machine's operational manual.
- 2
Verify that the machine's battery for absolute encoders is healthy if the machine requires homing after every power cycle.
- 3
Check if any recent parameter changes might have disabled automatic homing or altered homing requirements.
- 4
Confirm that the absolute position data is retained after power off; if not, investigate the battery backup system or absolute encoder.
- 5
Ensure the machine's control mode is set correctly for homing operation.