368

SERIAL DATA ERROR(INT)

Fanuc · Series 30i/31i/32i-MODEL B Plus

Hva betyr 368 ?

This internal alarm indicates an interruption in serial communication, possibly due to a disconnected cable, a Pulse coder failure, or electrical noise. Loss of serial data communication prevents the control unit from receiving vital feedback information.

Vanlige årsaker

  • Communication interruption with the Pulse coder
  • Cable disconnection in the feedback loop
  • Pulse coder failure
  • Noise interfering with serial data transmission

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check whether the feedback cable is not disconnected and whether the connector is properly plugged.

  2. 2

    Replace the Pulsecoder.

Se alle koder i denne manualen (38)
Verifisert teknisk data. Sist oppdatert: March 2026