Oversetter...
6

Inverter Overheat

Fanuc · Series 30i/31i/32i-MODEL B Plus

Hva betyr 6 ?

This alarm indicates an overheat condition within the Inverter (Servo Amplifier). Potential causes include motor overload, inadequate cabinet cooling, high ambient temperature, or improper seating of the control printed-circuit board, all of which can lead to thermal stress on the amplifier.

Vanlige årsaker

  • Motor operation exceeding its continuous rating.
  • Insufficient cooling capacity within the cabinet (e.g., clogged filters, failed fans).
  • Ambient temperature exceeding operational limits.
  • Faceplate (control printed-circuit board) not fully seated.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check that the motor is being used at or below its continuous rating.

  2. 2

    Inspect the cabinet cooling fans and filters to ensure sufficient cooling capacity.

  3. 3

    Verify that the ambient temperature is within acceptable operating limits.

  4. 4

    Ensure the faceplate (control printed-circuit board) is pushed in as far as it will go.

  5. 5

    Replace the Servo Amplifier if all other checks are satisfactory.

Se alle koder i denne manualen (38)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Series 30i/31i/32i-MODEL B Plus
Fanuc 6 support: Inverter Overheat analyse | ErrorLib