12
Grid Phase Failure
Fronius · Perfect Charging
Hva betyr 12 ?
This fault indicates an issue with the electrical grid connection, specifically a detected phase failure. This can prevent the battery charger from operating correctly or initiating a charging process, especially in three-phase systems.
Vanlige årsaker
- Loss of one or more phases in the multi-phase power supply to the charger.
- Significant voltage imbalance or drop in one or more phases.
- An issue with the electrical infrastructure supplying power to the charger.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify all incoming phases at the charger's input terminals using a multimeter to confirm voltage presence and balance.
- 2
Inspect the main circuit breaker and associated fuses for the charger's power supply for trips or blown conditions.