Oversetter...
203
TagID CAN Communication Failed
Fronius · Perfect Charging
Hva betyr 203 ?
CAN communication with the battery's TagID module could not be established. This prevents the charger from reading critical battery identification, configuration, and operational data, making proper charging impossible.
Vanlige årsaker
- A disconnected or physically damaged CAN bus cable connecting the charger to the TagID module.
- The TagID module itself is faulty, not powered, or its CAN interface has failed.
- Incorrect CAN bus settings such as baud rate, or improper termination resistors for the TagID connection.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the physical CAN bus cable connection to the TagID module for integrity and secure mating.
- 2
Check the TagID module for power presence and its operational status (e.g., indicator LEDs, if any).
- 3
Inspect CAN bus termination resistors and baud rate settings to ensure they are correctly configured for the network.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fronius Perfect Charging