57
Message Time Limit Exceeded (CAN)
Fronius · Perfect Charging
Hva betyr 57 ?
The charger did not receive an expected message from the battery via CAN bus within the allowed time frame. This indicates a delay or loss of communication packets, leading to a timeout and a communication failure.
Vanlige årsaker
- High latency or an intermittent connection on the CAN bus, causing messages to be delayed or dropped.
- The battery's BMS is slow to respond to queries or experiencing internal processing delays.
- Incorrect timeout settings configured in the charger's CAN communication parameters, making it too aggressive.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect the CAN bus wiring for proper shielding, grounding, and integrity to ensure reliable signal transmission.
- 2
Check the battery's BMS for any internal fault codes or indications of slow operation or processing overload.
- 3
Review the charger's CAN communication timeout parameters and adjust them if necessary to be more tolerant of network latency.