303

DC module overtemperature

Fronius · Primo GEN24 Operating Instructions

Hva betyr 303 ?

This code indicates that the DC module within the inverter has reached an excessively high temperature. This leads to a short-term interruption in energy feeding, after which the inverter will resume its startup routine once temperatures normalize.

Vanlige årsaker

  • Insufficient cooling due to blocked cooling air openings or a dirty heat sink.
  • High ambient temperatures exceeding the inverter's operating limits.
  • Internal fan malfunction or failure.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Clean and purge all cooling air openings and the heat sink of the inverter to ensure proper airflow.

  2. 2

    Verify that the inverter's installation location allows for adequate ventilation and is not exposed to excessive heat sources.

  3. 3

    Inspect internal cooling fans for proper operation and any obstructions.