305
No power being fed in, despite closed relay
Fronius · Primo GEN24 Operating Instructions
Hva betyr 305 ?
This code indicates that the inverter's internal relay is closed, but no power is being fed into the grid. This suggests a potential issue in the power path even though the switching element is engaged, causing a short-term interruption before the inverter attempts to restart.
Vanlige årsaker
- Failure or malfunction of internal power stage components despite relay closure.
- Grid impedance issues preventing power injection.
- Faulty internal measurement or control circuitry preventing detection of power flow.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
If this status code keeps recurring, contact your system engineer for diagnosis.
- 2
Perform an AC reset by cycling the automatic circuit breaker to potentially clear transient relay issues.
- 3
Verify the AC grid voltage and frequency are within the permissible operating range.