408
DC component measured in the grid too high
Fronius · Primo GEN24 Operating Instructions
Hva betyr 408 ?
This code indicates that an excessively high DC current component has been measured in the AC grid. Such a condition can indicate a fault within the inverter's power conversion stages or an external grid disturbance, typically causing the inverter to disconnect for safety.
Vanlige årsaker
- Internal fault within the inverter causing DC current injection into the AC grid.
- Malfunction of grid monitoring relays or sensors detecting DC components.
- Fault in the inverter's output filter or control.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
If the status code is displayed continuously, notify a Fronius-trained service engineer for diagnosis and repair.
- 2
Perform an AC reset to cycle the inverter and clear transient measurement errors.
- 3
Verify grid connection integrity and absence of external DC injection sources.