No communication possible with the Fronius Datamanager

Fronius · Primo GEN24 Operating Instructions

Hva betyr 420 ?

This code indicates a loss of communication between the inverter and the Fronius Datamanager. This means data logging, monitoring, and remote control functionalities via the Datamanager are currently unavailable.

Vanlige årsaker

  • Network cable disconnection or damage between the inverter and Datamanager.
  • IP address conflict or incorrect network settings.
  • Malfunction of the Datamanager unit itself or the inverter's communication interface.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer.

  2. 2

    Check the network cable connection between the inverter and the Fronius Datamanager for damage or secure connection.

  3. 3

    Verify network settings (e.g., IP addresses, subnet mask) for both the inverter and the Datamanager.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026