Oversetter...
456

Anti-islanding function is no longer being implemented correctly

Fronius · Primo GEN24 Operating Instructions

Hva betyr 456 ?

This code indicates that the anti-islanding function, a critical safety feature that prevents the inverter from operating when disconnected from the main grid, is no longer functioning correctly. This will typically cause the inverter to disconnect from the grid.

Vanlige årsaker

  • Malfunction of the anti-islanding detection hardware or software.
  • External grid conditions preventing correct detection.
  • Corruption of anti-islanding parameters.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for diagnosis of the anti-islanding circuitry.

  2. 2

    Perform an AC reset by cycling the automatic circuit breaker to re-initialize the function.

  3. 3

    Verify that grid parameters relevant to anti-islanding detection are correctly set.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fronius Primo GEN24 Operating Instructions
Fronius 456 support: Anti-islanding function is no longer b… | ErrorLib