Oversetter...
Poor Weld Properties (Inadequate Gas)

Inadequate/No Shielding Gas

Fronius · TPS i Welding Machine

Hva betyr Poor Weld Properties (Inadequate Gas) ?

Poor weld properties are observed due to an insufficient or completely absent supply of shielding gas. This compromises arc stability and weld protection from atmospheric contamination.

Vanlige årsaker

  • Pressure regulator malfunction.
  • Damaged or improperly connected gas hose.
  • Faulty gas solenoid valve.
  • Problem with the welding torch gas connection.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the gas pressure regulator for correct operation and set pressure.

  2. 2

    Check the gas hose for proper connection, kinks, or damage and replace if necessary.

  3. 3

    Verify the welding torch gas connection for security and absence of leaks.

Se alle koder i denne manualen (34)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder