Oversetter...
231-A041

CC%2 SOM 4 not possible

Heidenhain · TNC CNC Controllers

Hva betyr 231-A041 ?

This error indicates that Safety Operating Mode (SOM) 4 is not possible for the CC%2 controller. The common causes include Keylock Switch 1 not being in automatic mode (BA1), a defective Keylock Switch 1, or a wiring error.

Vanlige årsaker

  • Keylock switch 1 is not in automatic mode (BA1).
  • Keylock switch 1 is defective.
  • Wiring error related to Keylock switch 1.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Set Keylock switch 1 to automatic mode (BA1).

  2. 2

    Test the functionality of Keylock switch 1; verify its different positions and their corresponding electrical signals.

  3. 3

    Inspect the wiring connected to Keylock switch 1 for any breaks, shorts, or loose connections.

  4. 4

    Measure continuity across the contacts of Keylock switch 1 in each position to confirm proper operation.

Se alle koder i denne manualen (47)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Heidenhain TNC CNC Controllers