2001

High String Input Voltage

Huawei · SUN2000 Solar Inverter

Hva betyr 2001 ?

The open-circuit voltage of the PV array exceeds the maximum input voltage limit of the SUN2000 due to an excessive number of PV modules connected in series. This indicates a potential overvoltage condition for the inverter's DC input.

Vanlige årsaker

  • Excessive PV modules are connected in series in the PV array. Therefore, the open-circuit voltage exceeds the maximum input voltage of the SUN2000.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the number of PV modules connected in series in the PV string.

  2. 2

    Ensure that the PV string open-circuit voltage is no greater than the maximum operating voltage of the SUN2000.