F434

Emergency-Stop

Indramat · DIAX 04

Hva betyr F434 ?

The DIAX04 SSE-03VRS drive has received an Emergency-Stop command, typically from an external safety circuit. This initiates an immediate, controlled, and safe shutdown of the drive and connected motor. This is a critical safety function to prevent injury or damage during hazardous situations.

Vanlige årsaker

  • An external Emergency-Stop button was pressed.
  • A safety light curtain, safety gate switch, or other safety device was activated.
  • Fault in the external safety circuit (e.g., wiring short, component failure) falsely triggering the E-Stop.
  • Incorrect wiring or configuration of the E-Stop input to the DIAX04 SSE-03VRS drive.
  • Internal fault within the DIAX04 SSE-03VRS drive's safety input monitoring.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Identify and reset all activated Emergency-Stop buttons and external safety devices in the system.

  2. 2

    Inspect the entire E-Stop safety circuit (buttons, relays, wiring, and connections) for proper operation and integrity.

  3. 3

    Verify the E-Stop input status on the DIAX04 SSE-03VRS drive's diagnostics to confirm the signal is clear.

  4. 4

    Ensure the E-Stop wiring to the DIAX04 SSE-03VRS is correct and free from shorts or open circuits.

  5. 5

    If the E-Stop was not intentionally activated, systematically check each component of the external safety chain to find the false trigger.