E2819

Mains failure

Indramat · IndraDrive MPx02

Hva betyr E2819 ?

The IndraDrive MPx02 has detected a complete loss of the incoming AC mains power supply. This means the drive is no longer receiving power from the grid and will initiate a controlled shutdown or ride-through sequence based on its configuration, as it cannot sustain operation.

Vanlige årsaker

  • Main circuit breaker tripped or fuse blown for the entire system supplying the drive.
  • Emergency stop activated cutting off main power to the machine.
  • Power utility outage affecting the facility or a section of the plant.
  • Complete disconnection of the mains power cable to the drive.
  • Fault in the upstream power supply or distribution system.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the main circuit breaker or fuses supplying power to the entire machine or system for the IndraDrive MPx02 and restore power if tripped/blown.

  2. 2

    Verify that no emergency stop button or safety interlock has been activated, which would cut off mains power.

  3. 3

    Measure the incoming AC mains voltage at the drive's input terminals (L1, L2, L3) to confirm the complete absence of voltage.

  4. 4

    Inspect the mains power cable for any physical damage or disconnections.

  5. 5

    Contact the power utility or check the building's main electrical panel if the entire plant or section is without power.

Se alle koder i denne manualen (56)