E3105

Validation error of safety related operating mode

Indramat · IndraDrive MPx02

Hva betyr E3105 ?

The IndraDrive MPx02's integrated safety function has detected an invalid or inconsistent configuration for a safety-related operating mode (e.g., Safely Limited Speed, Safe Operating Stop). This prevents the drive from entering a verified safe mode, indicating a potential safety risk and requiring re-configuration.

Vanlige årsaker

  • The selected safety-related operating mode is not configured correctly or completely.
  • A conflict exists between different safety function settings or parameters.
  • Parameters defining the operating mode have been corrupted or improperly modified.
  • The requested safety-related operating mode is not supported by the current safety configuration or firmware version.
  • Incorrect sequence of activation for safety operating modes.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Using the safety configuration tool, review the settings for all safety-related operating modes to ensure they are correctly defined and do not conflict.

  2. 2

    Verify that the parameters for the specific safety-related operating mode intended for use are valid and match the machine's safety concept.

  3. 3

    Perform a re-validation of the entire safety configuration after any parameter changes.

  4. 4

    Check for any firmware updates or compatibility requirements for the safety module and the drive's main firmware.

  5. 5

    If the error persists, conduct a thorough review of the machine's safety concept and the drive's safety configuration, then contact Indramat safety service.