The axis failed to come to a complete stop within the allocated time after a safety-related stop command was issued. This indicates that the machine's deceleration was insufficient, or there was an uncontrolled movement during the stop, violating a safety stopping time requirement.

Vanlige årsaker

  • Insufficient braking torque or worn mechanical brakes.
  • Excessive inertia of the load for the configured stopping time.
  • Incorrectly configured safety stopping time parameter.
  • Faulty speed/position feedback preventing accurate monitoring of deceleration.
  • Drive internal fault preventing effective braking.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the mechanical brakes (if present) for wear and proper function, ensuring adequate stopping torque.

  2. 2

    Review the application's inertia and ensure the configured stopping time parameter (e.g., S-0-0XXX Safe Stopping Time) is realistic.

  3. 3

    Adjust the drive's deceleration ramps and braking parameters to achieve faster stopping times if mechanically possible.

  4. 4

    Verify the integrity and accuracy of the motor's speed and position feedback.

  5. 5

    Ensure the drive's power section and braking chopper are functioning correctly to dissipate regenerative energy.