Oversetter...
39

Index Length

Indramat · ServoDyn D Servo Drive

Hva betyr 39 ?

This error occurs when the system attempts to switch from Manual to Automatic mode, but the amount of material that has passed under the measuring wheel is greater than the configured part length. This implies a discrepancy in material tracking during a mode transition.

Vanlige årsaker

  • The measured material length exceeds the programmed part length when attempting to switch modes.
  • Incorrectly calibrated or malfunctioning measuring wheel encoder.
  • Parameter 21 (Length Correction) is not set correctly, leading to inaccurate material length calculations.
  • Manual material handling or process interruptions causing an unexpected length difference.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify that the index length is correct before attempting to switch from Manual to Automatic mode.

  2. 2

    Refer to Parameter 21 (Length Correction) in Chapter 4 for information on how to properly set and adjust index length.

  3. 3

    Inspect the measuring wheel encoder for proper calibration, physical damage, and accurate material measurement.

  4. 4

    Ensure that the part length parameter in the CLM01.3-M is correctly configured for the application.

  5. 5

    Review the operational procedure for mode switching to ensure it occurs at an appropriate point in the material processing cycle.

Se alle koder i denne manualen (51)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Indramat ServoDyn D Servo Drive