Oversetter...
61

Overspeed

Kone · CMXC-022 Frequency Control Upgrade Kit

Hva betyr 61 ?

An overspeed condition has been detected by the R&M Materials Handling Frequency Converter, or there is interference affecting the speed signal from the encoder connected to ENC1A. This can lead to uncontrolled motor speed, posing a safety risk if not corrected.

Vanlige årsaker

  • Motor overspeed detected
  • Interference in the speed signal connected to ENC1A

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the supply voltage

  2. 2

    Verify the load measurement operation and calibration

  3. 3

    Check the sensor cable grounding and inverter PE- connections

  4. 4

    Check or replace the speed sensor connected to ENC1A

Se alle koder i denne manualen (40)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Kone CMXC-022 Frequency Control Upgrade Kit