61
Overspeed
Kone · CMXC-022 Frequency Control Upgrade Kit
Hva betyr 61 ?
An overspeed condition has been detected by the R&M Materials Handling Frequency Converter, or there is interference affecting the speed signal from the encoder connected to ENC1A. This can lead to uncontrolled motor speed, posing a safety risk if not corrected.
Vanlige årsaker
- Motor overspeed detected
- Interference in the speed signal connected to ENC1A
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the supply voltage
- 2
Verify the load measurement operation and calibration
- 3
Check the sensor cable grounding and inverter PE- connections
- 4
Check or replace the speed sensor connected to ENC1A
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kone CMXC-022 Frequency Control Upgrade Kit